4 technical data, 1 general data and operating conditions, Technical data – Lenze EMF2180IB User Manual

Page 14: General data and operating conditions, 4technical data

Advertising
background image

4

Technical data

4.1

General data and operating conditions

14

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions

Range

Values

Order designation

EMF2180IB

Communication media (system)

CAN (ISO 11898)

Ethernet (100 Base TX, IEEE802.3u)

Number of nodes at the CAN bus

Max. 100

Baud rate

• For communication via CAN

• 20 kbit/s

• 50 kbit/s

• 125 kbit/s

• 250 kbit/s

• 500 kbit/s

• 1000 kbps

• For communication via Ethernet

• 10 Mbps

• 100 Mbits/s

Voltage supply (external) via

separate power supply unit

18 ... 30 V DC, max. 100 mA (in compliance with IEC/EN 61131-2)

Conformity and approval

CE See hardware manual of the used Inverter.

UL See hardware manual of the used Inverter.

EAC TP TC 020/2011

(TR ZU 020/2011)

Electromagnetic compatibility of

technical means

Eurasian Conformity

TR CU: Technical Regulation of Cus-

toms Union

TP TC 004/2011

(TR ZU 004/2011)

On safety of low voltage equipment

Operating conditions

Values

Deviations from standard

Climatic conditions

Storage 1 K3 to IEC/EN 60721-3-1

- 10 °C ... + 60 °C

Transport 2 K3 to IEC/EN 60721-3-2

- 10 °C ... + 70 °C

Operation 3 K3 to IEC/EN 60721-3-3

- 0 °C ... + 60 °C

Enclosure of the plugged

communication module

IP20

Degree of pollution

2 to IEC/EN 61800-5-1