3 data transfer via ethernet, Data transfer via ethernet, 7data transfer – Lenze EMF2180IB User Manual

Page 49

Advertising
background image

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

49

7

Data transfer

7.3

Data transfer via Ethernet

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3

Data transfer via Ethernet

The Engineering PC and the communication module communicate via a proprietary protocol which

is based on TCP/IP. The port number '22080' is used for the communication module.
The port number may have to be cleared if a firewall or something similar is used.
Port '3677' is used to search for fieldbus nodes.
Port '80' is required to operate the web server.

Tip!
The search via Ethernet is only possible within one network. The frames are not

transmitted via routers.

Ethernet communication manual
Here you'll find some detailed information relating to the Ethernet data frame structure.