Parameter reference

54

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C0150

C0200

C0202

Parameter | Name:

C0150 | Status word

Data type: UNSIGNED_16

Index: 24425 = 0x5F69

The binary interpretation of the displayed decimal value reflects the bit statuses of the status word:

• Bit 0: Ready for operation

• Bit 1: Dial-up connection is available

• Bit 2: Internal error

Value is bit-coded:

Bit 0 Ready for operation
Bit 1 Reserved

... ...

Bit 15 Reserved

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0200 | Software ID

Data type: VISIBLE_STRING

Index: 24375 = 0x5F37

During initialisation, the manufacturer's product code is used to determine which device is connected as node.

The display for the EMF2180IB communication module is "33S2180F_10000".

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0202 | Software ID (octet)

Data type: INTEGER_32

Index: 24373 = 0x5F35

In subcodes 1 ... 4, the corresponding octet of the manufacturer's product code is shown.
Display range

(min. value | unit | max. value)

-2147483647

2147483647

Subcodes

Info

C0202/1

1st octet

C0202/2

2nd octet

C0202/3

3rd octet

C0202/4

4th octet

Read access  Write access  CINH  PLC-STOP  No transfer