C1227, C1228, 9parameter reference – Lenze EMF2180IB User Manual

Page 64

Advertising
background image

9

Parameter reference

64

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C1227

C1228

C1229

Parameter | Name:

C1227 | Delay time for search frames

Data type: INTEGER_32

Index: 23348 = 0x5B34

Searching the CAN bus during the start of a PC program can lead to faults if a bus is heavily loaded. In order to

prevent this, a delay time between the transmission frames can be set. This, however, leads to an increase of the

total search time. If required, the time limit for the node search (

C1202

) has to be adapted.

Setting range

(min. value | unit | max. value)

Lenze setting

0

MS

100 0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Setting

Meaning

0

Quickest possible search

1 ... 10

Delay time 1 ms

11 ... 19

Delay time 10 ms

20 ... 29

Delay time 20 ms

...

...

90...100

Delay time 90 ms

Parameter | Name:

C1228 | DHCP activation

Data type: UNSIGNED_32

Index: 23347 = 0x5B33

This code enables access to the CAN bus system via the "Dynamic Host Configuration Protocol" (DHCP).

Changes that are made to the settings will be accepted after ...

• reconnection to the mains;

• a device reset via code

C1229

(with the value "2" or "3").

The parameterisation of this code is then stored with mains failure protection in the communication module

immediately.
Selection list

(Lenze setting printed in bold)

0 Not activated
1 activated

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C1229 | Activation of IP settings, device reset

Data type: UNSIGNED_32

Index: 23346 = 0x5B32

This code ...

• stores the IP adress, the network mask, and the gateway address with mains failure protection;

• executes a device reset;

• enables the combination of the two actions mentioned first.

Selection list

(Lenze setting printed in bold)

Info

0 No function
1 Save IP settings

The IP adress, the network mask, and the gateway

address are saved in the communication module with

mains failure protection.

2 Device reset

Reset of the communication module

3 Saving IP settings and device reset

Storage of the IP address, network mask, and gateway

address with a subsequent device reset.

Read access  Write access  CINH  PLC STOP  No transfer

Advertising