2 commissioning with the web server, Commissioning with the web server, 6commissioning – Lenze EMF2180IB User Manual

Page 36

Advertising
background image

6

Commissioning

6.2

Commissioning with the web server

36

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2

Commissioning with the web server

Commissioning via the integrated web server is an alternative to commissioning with the "System

bus configurator".
The integrated web server makes it possible to configure the communication module by means of

a simple web browser.

The following function is available from version 1.7 onwards!

When the DHCP function is activated, the DHCP server automatically assigns an IP address to the

communication module.
If an invalid combination of IP address and subnet mask is detected, an error message is output via

the web page:

2180FEW019

In this case, the two values (IP address, subnet mask) will not be saved in the EEPROM of the

communication module.
The gateway IP is only valid if it is inside the user's own network (exception: gateway IP ’0.0.0.0’).

Advertising