6commissioning – Lenze EMF2180IB User Manual

Page 34

Advertising
background image

6

Commissioning

6.1

Commissioning with the Lenze "System bus configurator"

34

Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5. Enter the MAC address of the nameplate or identify it online.
6. Enter the desired IP address and transfer it to the communication module online.

Afterwards an automatic reset is carried out by the communication module, which may

take some seconds (observe LEDs).

7. When the communication module is ready for operation again, change to the General tab.
8. Click the Diagnostics tab.

An attempt is made to establish a connection to the communication module. First, a

comparison is made, checking whether the CAN parameters configured are identical to

those in the device. If this is not the case, an adjustment is carried out.

9. Then search the CAN bus for nodes connected.

10. Confirm the confirmation prompt with Yes, or select No to abort the diagnostics process.

Advertising