RS485 interface


RS485 interface is available at the 4 pins screw terminal connector TB508. Up to 32 drives can be
daisy chained by connecting their “+” and “-“ terminals using twisted pair wire. Connect termination
resistor between “+” and “-“ terminals of the last drive in network. See figure below for connection.

TABLE 11

TB508 RS485 CONNECTOR

PIN #

Function

1

RS485 Data +

2

RS485 Data +

3 RS485

Data

-

4 RS485

Data

-





RS485 Network connection. Use twisted pair wire with optional shield. Connect shield to the
earth ground (optional).


120

Last Drive in the network

Additional Drives (Up to 32 total)

Network Master (Computer or PLC)

terminated with resistor