SimpleServo 500/600/i1000 User Manual Rev 3.4

6.3 I/O Group

6.3.1

Programmable digital input

N/A

Input not assigned and has no effect on drive operation.

External Fault

Input serves as external fault input. Servo will stop and indicate fault if this input is
activated.

Stop

In velocity or current mode sets input reference to 0 regardless of voltage on analog input.

Reverse

Sign of input reference voltage is reversed.

6.3.2

Programmable digital output

Not assigned

No function has been assigned for digital output

Zero Speed

Motor is at zero speed threshold set by ZERO SPEED parameters in Velocity Limits
Group

In Speed Window

Motor shaft RPM is within specified speed window as specified in Velocity Limits Group.

Current Limit

Drive current output has exceeded the limit established by the CURRENT LIMIT setting
in the Drive Parameters dialog box.

Run Time Fault

A fault has occurred. Refer to Section 8.2 for details on faults.

Current limit

Motor has reached maximum current as set by current limit parameter

6.3.3 Analog

output


SimpleServo has one analog output with 10-bit resolution. Signal scaled to +- 10V. The analog output
can be assigned to following functions:

• Phase current RMS

• Phase current Peak

• Motor Velocity

• Phase R current

• Phase S current

• Phase T current

• Iq current (Torque)

• Id current (Direct component)


6.3.4

Analog output current scale (Volt/amps)


Applies scale for functions representing CURRENT values.