9.5 Enabling SSi1000 drives
SimpleServo SSi must be enabled before it can index. SSi drive’s can be enabled by executing
“ENABLE” statement. You can set hardware enable input A2 (see table 7) to active state.
Enable input configured as active:
System will get enabled only if this input active (ON). If you execute “ENABLE” statement but input A2
not active system will be placed in fault state. If during the operation input A2 will be deactivated
system will be placed in fault state as well.
Enable input configured to be active
63