Replace the Fuse (360X-Plus II Only)

134

14068L-001 Rev. A

X-Plus II User Guide

1/11/07

Replace the Fuse (360X-Plus II Only)

The instructions that follow are for the 360X-Plus II series printers only. The 300X-Plus II and
600X-Plus II fuses are not user-replaceable.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is
provided as a spare. The end caps of the fuse must bear the certification mark of a known
international safety organization (see

Figure 11 on page 25

).

To replace a faulty fuse, complete these steps:

1.

Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (

Figure 36

).

Figure 36 • AC Power Entry Module

2.

Remove the faulty fuse and install a new fuse in the in-circuit position (

Figure 37

).

Caution • Turn the AC power switch off (O) and remove the power cord before performing
this procedure.

1

Power switch

2

Fuse holder

3

AC power entry module

4

Small-blade screwdriver

Important •

If you use the spare fuse, be sure to order a replacement fuse from an

authorized Brady distributor. The spare fuse should be the exact type and rating as the
original in-circuit fuse.