Brady X-Plus II User Manual

Page 97

Advertising
background image

87

Configuration

Control Panel Parameters

1/11/07

X-Plus II User Guide

14068L-001 Rev. A

Select Resynch Mode
This parameter determines how the printer reacts if the label
synchronization is lost and the label top is not where expected.

Default: FEED MODE

Selections: FEED MODE, ERROR MODE

FEED MODE—If the label top is not where expected, the printer feeds

a blank label to find the label top position.

ERROR MODE—If the label top is not where expected, the printer

stops, enters Pause mode, displays the message

Error Condition

Feed Label

, flashes the

ERROR

light, and asserts the Service

Required signal (pin 10 on the Applicator Interface Connector).

To resynch the media to the top of the label in Error mode, press

PAUSE

to exit Pause mode. The ERROR light stops flashing, and the

Service Required signal is deactivated. The action of the printer is
determined by the

Head Close

configuration selection (see

Select

Head Close Option on page 82

).

To change the value shown:

1.

Press the left or right oval to toggle between the options.

These parameters are automatically set during the calibration procedure
and should be changed only by a qualified service technician. Refer to the
ZPL II Programming Guide for information on these parameters.

To skip these parameters:

1.

Press

NEXT/SAVE

repeatedly.

Table 9 • Printer Parameters (Sheet 24 of 26)

Parameter

Action/Explanation

RESYNCH MODE
- FEED MODE +

WEB S. 073

- +

MEDIA S. 075
- +

RIBBON S. 071

- +

TAKE LABEL

- +

MARK S. 000
- +

MARK MED S. 000

- +

MEDIA LED 082

- +

RIBBON LED 008

- +

MARK LED 005
- +