171

Data Ports

Applicator Interface Connector

1/11/07

T408M/T408M-R User Guide

14178L-001 Rev. A

6

REPRINT

Input

• If the Reprint feature is enabled, this input must be

asserted LOW to cause the printer to reprint the last
label.

• If the Reprint feature is disabled, this input is ignored.

7

+28 V

(Fused at 500 mA.)

Caution • Replace
the fuse only with
one of the same
type and rating.

Power

The Interface Power Supply. Supplies power to external
sensors as required.

Note •

If operating with 28V signals only, pin 7

may be used to supply power to pin 2, which
creates a non-isolated mode of operation.

8

POWER GROUND

(+28 V DC Return)

Ground

The Interface Power Ground.

Note •

If pin 7 is used to supply power to pin 2,

use this pin to ground pin 1.

9

10

SERVICE
REQUIRED

Output

Asserted LOW in the following circumstances:

• the media cover is open

• the printhead is open

• the ribbon or media is out

• the printer is paused

• an operational fault occurs

• a Resynch error occurs while the applicator Resynch

mode is set to Error mode

11

END PRINT

Output

• MODE 0—The applicator port is OFF.

• MODE 1—Asserted LOW only while the printer is

moving the label forward; otherwise deasserted HIGH.

• MODE 2—Asserted HIGH only while the printer is

moving the label forward; otherwise deasserted LOW.

• MODE 3—(Default) Asserted LOW for 20

milliseconds when a label is completed and positioned.
Not asserted during continuous printing.

• MODE 4—Asserted HIGH for 20 milliseconds when a

label is completed and positioned. Not asserted during
continuous printing.

12

MEDIA OUT

Output

Asserted LOW while there is no media in the printer.

Table 20 • Applicator Interface Connector Pin Configuration (Continued)