Data Ports

Applicator Interface Connector

1/11/07

T408M/T408M-R User Guide

14178L-001 Rev. A

6

REPRINT

Input

• If the Reprint feature is enabled, this input must be

asserted LOW to cause the printer to reprint the last
label.

• If the Reprint feature is disabled, this input is ignored.

7

+28 V

(Fused at 500 mA.)

Caution • Replace
the fuse only with
one of the same
type and rating.

Power

The Interface Power Supply. Supplies power to external
sensors as required.

Note •

If operating with 28V signals only, pin 7

may be used to supply power to pin 2, which
creates a non-isolated mode of operation.

8

POWER GROUND

(+28 V DC Return)

Ground

The Interface Power Ground.

Note •

If pin 7 is used to supply power to pin 2,

use this pin to ground pin 1.

9

10

SERVICE
REQUIRED

Output

Asserted LOW in the following circumstances:

• the media cover is open

• the printhead is open

• the ribbon or media is out

• the printer is paused

• an operational fault occurs

• a Resynch error occurs while the applicator Resynch

mode is set to Error mode

11

END PRINT

Output

MODE 0—The applicator port is OFF.

MODE 1—Asserted LOW only while the printer is

moving the label forward; otherwise deasserted HIGH.

MODE 2—Asserted HIGH only while the printer is

moving the label forward; otherwise deasserted LOW.

MODE 3—(Default) Asserted LOW for 20

milliseconds when a label is completed and positioned.
Not asserted during continuous printing.

MODE 4—Asserted HIGH for 20 milliseconds when a

label is completed and positioned. Not asserted during
continuous printing.

12

MEDIA OUT

Output

Asserted LOW while there is no media in the printer.

Table 20 • Applicator Interface Connector Pin Configuration (Continued)