Calibration problems – Brady X-Plus II User Manual

Page 156

Advertising
background image

Troubleshooting
Calibration Problems

146

14068L-001 Rev. A

X-Plus II User Guide

1/11/07

Calibration Problems

Table 13

identifies problems with calibration, the possible causes, and the recommended

solutions.

Table 13 • Calibration Problems

Problem

Possible Cause

Recommended Solution

Loss of printing
registration on labels.
Excessive vertical
drift in top-of-form
registration.

Improperly positioned media
guides.

Ensure that the media guides are properly
positioned.

Media type set incorrectly.

Set the printer for the correct media type
(non-continuous or continuous). See

Set Media

Type on page 66

.

Dirty platen roller.

Clean the platen roller according to the
instructions in

Clean the Printhead and Platen

Roller on page 125

.

Auto Calibrate failed.

Improperly loaded media or
ribbon.

Ensure that media and ribbon are loaded
correctly.

The sensors could not detect the
media or ribbon.

Manually calibrate the printer. See

Calibrate

Media and Ribbon Sensor Sensitivity on page 77

.

The sensors are dirty or
positioned improperly.

Ensure that the sensors are clean and properly
positioned.

Advertising