Troubleshooting
Print Quality Problems

144

14068L-001 Rev. A

X-Plus II User Guide

1/11/07

Printing too light or
too dark over the
entire label

The media or ribbon is not
designed for high-speed
operation.

Replace supplies with those recommended for
high-speed operation.

You are using an incorrect
combination of media and
ribbon for your application.

1.

Switch to a different type of media or ribbon
to try to find a compatible combination.

2.

If necessary, consult an authorized Brady
distributor for information and advice.

You are using ribbon with
direct thermal media.

Direct thermal media does not require ribbon. To
check if you are using direct thermal media,
perform the label scratch test in

When to Use

Ribbon on page 28

.

If you are using ribbon intentionally with direct
thermal media, increase the darkness level, but
note that high darkness levels may decrease
printhead life. You may wish to perform the

FEED Self Test on page 154

to determine the

ideal darkness setting.

Incorrect or uneven printhead
pressure.

Set the pressure to the minimum needed. See

Adjust Printhead Pressure and Toggle Position
on page 53

.

Smudge marks on
labels

The media or ribbon is not
designed for high-speed
operation.

Replace supplies with those recommended for
high-speed operation.

Misregistration/skips
labels

The printer is not calibrated.

Recalibrate the printer.

The media sensor is not
positioned correctly.

Perform media sensor position adjustment.

Improper label format.

Use correct label format.

Misregistration and
misprint of one to
three labels

The platen roller is dirty.

See

Clean the Printhead and Platen Roller

on page 125

.

The media sensor is not
positioned correctly.

Place the media sensor in the proper position.

Media does not meet
specifications.

Use media that meets specifications.

Table 12 • Print Quality Problems (Continued)

Problem

Possible Cause

Recommended Solution