Brady X-Plus II User Manual

Page 95

Advertising
background image

85

Configuration

Control Panel Parameters

1/11/07

X-Plus II User Guide

14068L-001 Rev. A

Set the Printhead Resistor Value

Caution • This parameter should be changed only by qualified service
personnel. Do not set the value higher than that shown on the printhead.
Setting a higher value may damage the printhead.

This value is preset at the factory to match the resistance value of the
printhead. It does not need to be changed unless the printhead or the main
logic board is replaced.

Initial Value: Factory-set to match the printhead shipped with your printer.

Default Value: 0500

Range: 0488 to 2000

To set the printhead resistor value:

1.

Before replacing the printhead, look for the label that shows the
resistance value (

Ω

value) of the new printhead. Make note of this

setting before installing the new printhead.

2.

Press the left oval to move to the next digit position.

3.

Press the right oval to increase the value of the digit.

Set the Verifier Port
The auxiliary port is used to determine how the printer reacts to an online
verifier. For more information on the operation of the optional verifier,
refer to the documentation provided with that option.

Default: OFF

Selections: OFF, VER-RPRNT ERR, VER-THRUPUT

OFF: The verifier port is off.

VER-RPRNT ERR: Label reprinted if verifier detects an error. If a

bar code is near the upper edge of the label, the label is fed out far
enough to be verified and then backfed to allow the next label to be
printed and verified.

VER-THRUPUT: Allows greatest throughput but may not indicate a

verification error immediately upon detection. May print from one to
three labels before an error is recognized and printing stops.

To change the value shown:

1.

Press the left or right oval to scroll through the options.

Table 9 • Printer Parameters (Sheet 22 of 26)

Parameter

Action/Explanation

HEAD RESISTOR
- 0500 OHMS +

VERIFIER PORT

OFF

Advertising