12

Rockwell Automation Publication 193-UM009B-EN-P - February 2013

Chapter 4 Quick Start

Terminal Setup

To scroll through the items on the screen, press the SEL key. To change the value
of a selected item, press the Increment or Decrement key. To commit the new
value for use, press the Enter (return arrow) key. To exit this screen, press the
ESC

key.

Network Who Screen

The terminal searches for all devices on the network and reports the devices it has
found on the Network Who screen. Use the Increment or Decrement key to
scroll through devices. Press Enter (return arrow) to invoke the Device Choices
menu.

Device Choices Menu

This menu allows the user to choose what operation is to be performed for the
selected device. The terminal only displays choices that are appropriate for the
selected device. The Increment and Decrement keys allow the operator to scroll
through the selections. The Enter key will advance to the selected operation.

Powerup delay
in seconds

Fixed Address
setting OR the
starting address for
auto address

Enable = AutoBaud enabled

Disable = Use fixed Baud Rate

Fixed Baud
Rate setting

Enable = Auto addressing on power up

Disable = Use fixed network address

Searching at this address

Currently
selected device

Device address

“-“=Device is not faulted

“~” = Device is faulted

Currently selected operation