Rockwell Automation 193-DNCT DeviceNet Configuration Terminal User Manual User Manual
Page 34
![background image](/manuals/577423/34/background.png)
30
Rockwell Automation Publication 193-UM009B-EN-P - February 2013
Chapter 7 Copy Cat Menu
first screen will allow the operator to select where the data will be stored, either to
an existing file or a new file:
After selecting a file, you will be able to name/rename it:
When done editing the file name, press the Enter key to start uploading:
Selected file
New
unnamed
“empty” file
Existing Copy
Cat file
names
File name the
Copy Cat data will
be saved to
Selected
Character; use
the Sel key to
move the cursor
to the right to
select the next
character
Use the Inc/Dec key to move the cursor to change the character. The numeric
keypad can be used to enter a number into the file name
Upload progress bar
Currently uploading parameters. Note:
Will display ScanList for Copy Cat of an
Allen-Bradley DeviceNet™ Scanner