Page 70

Advertising
background image

Settings for 1771–AS and 1771–ASB Series A, B, C and D Remote I/O Adapters

B–8

Publication 1771ĆUM001A-US-P - February 2000

FigureB.8

Module Switch Assembly Settings for 1771-AS and

1771-ASB series A and B Adapters for PLC-5 Family

Processors without Complementary I/O

1 2 3 4 5 6 7 8

O

N
O

F

F

O

N
O

F

F

1 2 3 4

First I/O group number

(Table B.E)

I/O rack number

(Table B.E)

Always OFF

Address Switch Assembly

(SW-1)

Switch Assembly

(SW-2)

Pressed in at top

Closed (ON)

Pressed in at bottom

Open (OFF)

10821-I

Maximum I/O Rack Distance

ON - 10,000 cable ft. max. (57.6K baud)

OFF - 5,000 cable ft. max. (115.2K baud)

TableB.E

I/O Rack Selection for PLC-5 Family without

Complementary I/O

I/O Rack

Number

Switch Selections

1

2

3

4

5

6

First I/O Group

Number

Switch Selections

7

8

1

On

On

On

On

On

Off

0

On

On

2

On

On

On

On

Off

On

2

On

Off

3

On

On

On

On

Off

Off

4

Off

On

4

1

On

On

On

Off

On

On

6

Off

Off

5

1

On

On

On

Off

On

Off

6

1

On

On

On

Off

Off

On

7

1

On

On

On

Off

Off

Off

1

Valid for PLC-5/25 processors only