Rockwell Automation 1771-ASB/E Remote I/O Adapter User Manual User Manual

Page 72

Advertising
background image

Settings for 1771–AS and 1771–ASB Series A, B, C and D Remote I/O Adapters

B–10

Publication 1771ĆUM001A-US-P - February 2000

Figure B.10

Module Switch Assembly Settings for 1771-AS, -ASB series

A andB Adapters for PLC-5 Family Processors with

Complementary I/O

1 2 3 4 5 6 7 8

O

N
O

F

F

O

N
O

F

F

1 2 3 4

First I/O group number

(Table B.G)

I/O rack number

(Table B.G)

Always OFF

Address Switch Assembly

(SW-1)

Switch Assembly

(SW-2)

ON - Primary chassis

OFF - Complementary chassis

Pressed in at top

Closed (ON)

Pressed in at bottom

Open (OFF)

ON - Primary chassis

OFF - Complementary chassis

Always ON

10822-I

Maximum I/O Rack Distance

ON - 10,000 cable ft. max. (57.6K baud)

OFF - 5,000 cable ft. max. (115.2K baud)

Table B.G

I/O Rack Selection for PLC-5 Family with Complementary I/O

I/O Rack

Number

Switch Selections

4

5

6

First I/O Group

Number

Switch Selections

7

8

1

On

On

Off

0

On

On

2

On

Off

On

2

On

Off

3

On

Off

Off

4

Off

On

4

1

Off

On

On

6

Off

Off

5

1

Off

On

Off

6

1

Off

Off

On

7

1

Off

Off

Off

1

Valid for PLC-5/25 processors only

Advertising