Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 111
Advertising

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
111
Standard Drive Parameters
Appendix A
[Pr - 9.59]
Scope Scaling
Range
32-bytes character string
Data Size
32 digits
Digits
Digits
Description
0…7
Channel A Scale
8…15
Channel A Offset
16…23
Channel B Scale
24…31
Channel B Offset
Default 0x00000000000000000000000000000000
Ultraware Name
Displayed Units
Range
1-byte character string
0 = Metric
1 = English
2 = User units
Default
0
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.60]
Displayed Units
Ultraware Name
Displayed Units
Range
1-byte character string
0 = Metric
1 = English
2 = User units
Default
0
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
Advertising
This manual is related to the following products: