Appendix A
Standard Drive Parameters
[Pr - 0.05]
Auxiliary Function Selection 1
Applicable Operating Mode
All
Data Size
4 digits
Digit 0
Encoder Back-up Battery
Ultraware Name
Encoder Back-up Battery
Range
Value
Description
0x0
Battery Installed
0x1
Battery Not Installed
Default
0
Digit 1
Velocity Observer
Ultraware Name
Velocity Observer
Range
Value
Description
0x0
Disable
0x1
Enable
Default
0
Digit 2
Alternative Gain Change Enable
Ultraware Name
Gain Change Enable
Range
Value
Description
0x0
Disable
0x1
Enable
Default
0x0
Digit 3
Emergency stop input
Range
Value
Description
0x0
Disable
0x1
Enable
Default
0
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
Modbus Address
Advertising