Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual

Page 59

Advertising
background image

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

59

Standard Drive Parameters

Appendix A

[Pr - 0.15]

Allocation of Input Signals 6

Data Size

4 digits

Digit

Description Default

Unmapped

IO

Status

0

Reset multi-turn data of absolute
encoder (R_ABS)

0x0

OFF

1

Gain bank select (BANK_SEL)

0x0

OFF

2

Reserved

0x0

OFF

3

Reserved

0x0

OFF

When Enabled

Servo-Off -> Setting

(1)

(1)

Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61

.

Applicable Operating Mode

All

Modbus Address

16

[Pr - 0.16]

Allocation of Input Signals 7

Data Size

4 digits

Digit

Description

Default

Unmapped IO
Status

0

Home sensor (H_SENS)

0x0

OFF

1

Start homing (SHOME)

0x0

OFF

2

Stop indexing (STOP)

0x0

OFF

3

Pause indexing (PAUSE)

0x0

OFF

When Enabled

Servo-Off -> Setting

(1)

(1)

Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61

.

Applicable Operating Mode

Indexing

Modbus Address

17

[Pr - 0.17]

Allocation of Input Signals 8

Data Size

4 digits

Digit

Description

Default

Unmapped IO
Status

0

Index select 0 input (I_SEL0)

0x0

OFF

1

Index select 1 input (I_SEL1)

0x0

OFF

2

Index select 2 input (I_SEL2)

0x0

OFF

3

Index select 3 input (I_SEL3)

0x0

OFF

When Enabled

Servo-Off -> Setting

(1)

(1)

Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61

.

Applicable Operating Mode

Indexing

Modbus Address

18