Appendix A
Standard Drive Parameters
[Pr - 1.26]
Hysteresis of Gain Switching
Ultraware Name
Gain Switching: Hysteresis of Gain Switching
Range
0…10,000
Default
0
Units
-
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Velocity, Preset
Modbus Address
[Pr - 1.27]
Position Gain Switching Time
Ultraware Name
Gain Switching: Level of Gain Switching
Range
0…10,000
Default
0
Units
x 200 μs
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Velocity, Preset
Modbus Address
[Pr - 1.28]
2nd Velocity Regulator P Gain
Ultraware Name
2nd Regulator Gain: P
Range
0…10,000
Default
60
Units
-
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Velocity, Preset
Modbus Address
[Pr - 1.29]
2nd Velocity Regulator I Gain
Ultraware Name
2nd Regulator Gain: Integrator Gain
Range
0…60,000
Default
26
Units
-
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Velocity, Preset
Modbus Address