Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual

Page 76

Advertising
background image

76

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

Appendix A

Standard Drive Parameters

[Pr - 1.26]

Hysteresis of Gain Switching

Ultraware Name

Gain Switching: Hysteresis of Gain Switching

Range

0…10,000

Default

0

Units

-

When Enabled

Immediately

Applicable Operating Mode

Follower, Analog Velocity, Preset

Modbus Address

126

[Pr - 1.27]

Position Gain Switching Time

Ultraware Name

Gain Switching: Level of Gain Switching

Range

0…10,000

Default

0

Units

x 200 μs

When Enabled

Immediately

Applicable Operating Mode

Follower, Analog Velocity, Preset

Modbus Address

127

[Pr - 1.28]

2nd Velocity Regulator P Gain

Ultraware Name

2nd Regulator Gain: P

Range

0…10,000

Default

60

Units

-

When Enabled

Immediately

Applicable Operating Mode

Follower, Analog Velocity, Preset

Modbus Address

128

[Pr - 1.29]

2nd Velocity Regulator I Gain

Ultraware Name

2nd Regulator Gain: Integrator Gain

Range

0…60,000

Default

26

Units

-

When Enabled

Immediately

Applicable Operating Mode

Follower, Analog Velocity, Preset

Modbus Address

129