Modbus Protocol
Chapter 1
3001
/ABS-DT
Position Strobe
bit
[0]
/START
Motor Moving Enable
bit
[1]
/Z-CLP
Zero Speed Clamp Enable
bit
[2]
/GEAR
2nd Electronic Gear Bank Selection
bit
[3]
/R-ABS
Reset multi-turn data of Absolute Encoder
bit
[4]
-
Reserved -
[5]
/SHOME
Start Homing
bit
[6]
/STOP
Stop Indexing
bit
[7]
/PAUSE
Pause Indexing
bit
[8]
/I-SEL0
Index Select 0 Input
bit
[9]
/I-SEL1
Index Select 1 Input
bit
[10]
/I-SEL2
Index Select 2 Input
bit
[11]
/I-SEL3
Index Select 3 Input
bit
[12]
/I-SEL4
Index Select 4 Input
bit
[13]
/I-SEL5
Index Select 5 Input
bit
[14]
/H_STOP
Stop Homing
bit
[15]
3002
/START_I
Start Index
bit
[0]
/BANK_SEL
Gain Bank Select
bit
[1]
-
Reserved -
[2…15]
Input Function Control - Holding Registers
Modbus
Address
I/O Function
Description
Unit
Position
Bit