Variable roll monitoring (mor) – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 38

38
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Chapter 3
General Commands (ASCII)
Variable Roll Monitoring (MOR)
Figure 2 - Variable Roll Monitoring (MOR) Command String Example
Attribute Value
Command MOR
Description
Set up variable roll monitor
Format
Data
STX ID # MOR SP P1 P2 : BSS ETX
Argument Description
SP
Sampling period range 0x01…0x64 (01…100 ms)
P1, P2
Variables to monitor. Range 0x00…0x1D
Usage Note
Sets up the variable roll monitoring. This command is sent to the drive prior to sending a
command. See
Figure 2
for command examples.
Response ACK
Next Command
STX ID # MOR : BSS ETX
Usage Note
Request to store data in the linear buffer (with a capacity of 100 data points). If the buffer
is full and data has not been retrieved, the buffer is emptied. If data is requested before
data is in the buffer, the drive sends ACK.
Response Format
STX ID $ MOR V1&V2&…Vn : BSS ETX
Response Data
Argument
Description
V1…Vn
Signed integer of variable length
Next Command
STX ID #ESC : BSS ETX
Usage Note
Send ESC to stop monitoring of the data.
Response ACK
#MOR (setting)
ACK
#MOR
$MOR
#MOR
$MOR
#ESC
ACK
PC
Servo
Time <200 ms
.
.
.