Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

95

Standard Drive Parameters

Appendix A

[Pr - 5.09]

Disabled Braking Speed

Ultraware Name

Stopping Functions: Braking Application Speed

Description

The Disabled Braking Speed is the feedback speed below
which the motor break is engaged, after disabling the
drive.

Range

0…1000

Default

100

Units

Rotary motors: rpm; Linear motors: mm/s

When Enabled

All

Applicable Operating Mode

Servo-Off -> Setting

Modbus Address

509

[Pr - 5.10]

Following Error Limit

Ultraware Name

Following Error Limit

Description

A following error fault occurs when the difference
between position command and actual position is greater
than this parameter.

Range

0…2,147,483,647

Default

99,999

Units

Counts

When Enabled

Immediately

Applicable Operating Mode

Follower

Modbus Address

Pr5-10[Lo] = 510, Pr5-10[Hi] = 511

[Pr - 5.11]

Reserved

When Enabled

Reserved for future use.

[Pr - 5.12]

AC line loss fault delay

Ultraware Name

AC Line Loss Fault Delay

Description

The AC Line Loss Fault is inhibited for this amount of time,
when a loss of AC power is detected.

Range

20…1000

Default

20

Units

ms

When Enabled

Servo-Off -> Setting

Applicable Operating Mode

All

Modbus Address

513