Indexing parameters – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 15
Advertising

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
15
Modbus Protocol
Chapter 1
Indexing Parameters
Special Index Group 0
Modbus
Address
Kinetix 3
Parameter
Modbus
Address
Kinetix 3
Parameter
4000
Index 0 Distance
Low
4005
Index 0 Accel Low
4001
Index 0 Distance
High
4006
Index 0 Accel High
4002
Index 0 Velocity
4007
Index 0 Dwell
4003
Index 0 Decel Low
4008
Index 0 Option
4004
Index 0 Decel High
4009
Index 0 Next Index
4010…4199
Reserved
Group 0 - Indexing System
Modbus
Address
Kinetix 3
Parameter
Modbus
Address
Kinetix 3
Parameter
5000
In00.00
5006
In00.03.Hi
5001
In00.01.Lo
5007
In00.04
5002
In00.01.Hi
5008
In00.05.Lo
5003
In00.02.Lo
5009
In00.05.Hi
5004
In00.02.Hi
5010
In00.06.Lo
5005
In00.03.Lo
5011
In00.06.Hi
5012…5199
Reserved