Monitor Variables

Appendix D

Compiled Variables

The tables below list variables that compile data to more effectively monitor
specific aspects of a Kinetix 3 drive

Variable 15 - Digital Inputs and Outputs

Monitoring of I/O status is provided by

Variable 15 - Digital Inputs and Outputs

.

Digital inputs

[Pr - 0.17]

[Pr - 0.18]

, and digital outputs

[Pr - 0.22]

[Pr - 0.27]

are compiled for this variable.

The table below lists the data bits in this variable.

Variable 25 - Digital Inputs

Digital input status is provided by

Variable 25 - Digital Inputs

. Digital inputs

[Pr

- 0.10]

[Pr - 0.14]

are compiled for this variable.

The table below lists the data bits in this variable.

Digital Outputs

EMG

Digital Inputs

Bit No.

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Data

DO6

DO5

DO4

SALM

DO3

DO2

DO1

EMG

DI10

DI9

DI8

DI7

DI6

DI5

DI4

DI3

DI2

DI1

Bit

Digital Input Function

Bit

Digital Input Function

0

Current Limit- Negative

10

Fault Reset

1

Current Limit- Positive

11

Integrator Inhibit

2

Alternate Gain Select

12

Negative Overtravel

3

Preset Direction

13

Operation Mode Override

4

Reset Multiturn Data

14

Position Strobe

5

Zero Speed Clamp

15

Positive Overtravel

6

Position Clear

16

Preset Select 0

7

Analog Speed Command Enable in Preset

17

Preset Select 1

8

Motor Moving Enable in Velocity Mode

18

Preset Select 2

9

2nd Electronic Gear Bank Selection