Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

49

Standard Drive Parameters

Appendix A

55

[Pr - 0.02]

Motor Basic Modes

Data Size

4 digits

Digit 0

Fault and Disable Braking

Ultraware Name

Stopping Functions: Fault and Disable Braking

Range

Value

Description

0x0

Brake and hold

0x1

Brake and release

0x2

Free stop

0x3

Free stop and hold

Default

0

Digit 1

Overtravel stop method

Ultraware Name

Stopping Functions: Over Travel Stop Method

Range

Value

Description

0x0

Stop by change of mode to Normal
Current. Set stopping current with
Overtravel Current Limit parameter

[Pr - 4.05]

.

0x1

Dynamic Brake

Default

0

Digit 2

Motor Forward Dir

Ultraware Name

Command Polarity

Range

Value

Description

0x0

The command signal is not inverted
so that a positive command value
results in clockwise rotation, as
viewed from shaft end.

0x1

The command signal is inverted so
that a positive command value results
in counter-clockwise rotation, as
viewed from shaft end.

Default

0

Digit 3

Power input

Ultraware Name

AC Line Loss Check

Range

Value

Description

0x0

Enables the following:

50…400W drive: Enable single-

phase open check

800…1.5kW drive: Enable three-

phase open check

0x1 Disable

0x2 Single-phase

input

Default

0

When Enabled

Servo-Off -> Setting

Applicable Operating Mode

All

Modbus Address

3