2–2

Installing Your Hardware

Publication 2755-6.3

Important Notes on Scanner Systems

The following illustrates the base/charger unit connected to the host
device and power supply.

Host

Power Supply

Base/Charger Unit

Be aware of the following when setting up your scanner system.

The gun operates up to 50 ft (15.24 m) from the host device
depending on the application environment.

The gun turns itself off after each successful data transmission to
conserve battery life.

Average life of a battery charge is 8 hours. Replace or recharge
the battery at the end of the work shift.

There is a 1-to-1 pairing of guns to bases. (You cannot have
multiple guns paired to one base or one gun paired to multiple
bases.)

You need to pair the scanner with the base/charger unit after
replacing the battery in the scanner gun. Refer to page 2–16 for
information regarding pairing the scanner to the base/charger
unit.

The base/charger unit cannot be placed in an enclosure. RF
communication between the gun and the base/charger unit will be
affected by the enclosure. However, you should protect the
base/charger unit from airborne contaminants.

1. Unpacking the Equipment

Remove the scanner, base/charger unit, power supply, and host
interface cable from their packing and inspect for physical damage.
If there is damage, contact Allen-Bradley Global Technical Services
(GTS) at (216) 646-6800.