5. The input and output line of the 8720MC-RPS units must be

separated from the output line of the inverter unit as far as
possible.

6. Wiring of the control signal must be terminated within the

control cabinet. Should the control cable be needed to extend
out of the control cabinet, it is recommended to use shielded
cables. When ferrite cores are used, install them possibly to the
side of the 8720MC-RPS units. The following are the ferrite
cores for the control cables recommended.

ZCAT2032-0930 (Inside diameter 9 +/- 1mm) : TDK

ZCAT2035-1330 (Inside diameter 13 +/- 1mm) : TDK

7. For notes on wiring to the other equipment and motors to be

connected with the 8720MC-RPS, refer to the manuals of
relevant equipment.

4-31

Wiring