Rockwell Automation GV3000/SE AC Drive Ver. 6.06 Hdwe Ref., Installation, and Troubleshooting Manual User Manual

Page 104

Advertising
background image

A-2

GV3000/SE AC Drive Hardware Reference, Version 6.06

Table A.2 – Environmental Condition

Condition

Specification

Operating Temperature (Ambient)

0

°

to

+

40

°

C

(

32

°

to

104

°

F

)

Storage Temperature (Ambient)

-40

°

to

+

65

°

C

(−

40

°

to

+

149

°

F

)

Humidity

5 to 95% (non-condensing)

Table A.3 – Terminal Strip Input Specifications

Signal Type

Terminal(s)

Specification

Speed Reference Input

12-15

10 V (@ 50K ohm input

impedance or 20 mA)

Digital Inputs (1 - 8)

16

+24 VDC Isolated Supply

17

Remote/Local (Default)

18

Ramp1/Ramp2 (Default)

19

Forward/Reverse (Default)

20

Function Loss

21

Run/Jog

22

Reset

23

Stop

24

Start

Table A.4 – Terminal Strip Output Specifications

Signal Type

Terminal(s)

Specification

Analog Output

10 -11

scaled signal

0-10 VDC or 4-20 mA

Snubber Resistor

26 - 27

Used with older Snubber

Resistor Braking Kits,

such as the M/N 2DB4010

series, that require a gate

turn-on signal from the

drive.

Table A.5 – Terminal Strip RS-232 Specifications

Signal Type

Terminal(s)

Specification

RS 232 Communications

1

XMIT

2

RECV

3

COMMON

Advertising