C-4
GV3000/SE AC Drive Hardware Reference, Version 6.06
C.3.1 Installing AC Mains Filters M/N 2DF4283, 2DF4284, 2DF4285, and
2DF4286
Use the following guidelines to mount the GV3000SE drive to the AC Mains Filter and
then mount the drive/filter assembly to a panel:
•
Attach the GV3000/SE drive to the AC Mains Filter. See figure C.1. No other type of
mounting is permitted. The required mounting hardware is supplied with the filter.
•
Attach the GV3000/SE drive/AC Mains Filter assembly to a panel or wall. See figure
C.1 and table C.2 for mounting dimensions. The panel/wall surface does not have to
be conductive, although it is preferable. The hardware for mounting the drive/filter
assembly to the panel/wall must be supplied by the user.
•
For 25-60 HP drives, cover kit M/N 2CK4160 is required.
Continue with section C.4.
Figure C.1 – AC Mains Filter Dimensions
H
G
J
K, Conduit Entry
M5 Nuts
GV3000/SE
Drive
Mounts on Top
of Mains Filter
(Screws
Provided)
Flexible
Conduit
(Provided)
G
A
D
E
F
C B
D
E
F
Top View
(Filter Only, Cover Removed)
L1
L2
L3 E(GND)
AC Mains
Filter
AC
Filter
Mains
Front View
(Filter Only)
Side View
(Filter and Drive)
See table C.2 for dimensions.
Note that for 25-60 HP drives,