Rockwell Automation GV3000/SE AC Drive Ver. 6.06 Hdwe Ref., Installation, and Troubleshooting Manual User Manual

Page 44

Advertising
background image

3-8

GV3000/SE AC Drive Hardware Reference, Version 6.06

Standard reactors can be used on GV3000/SE drives with carrier frequency settings up to 8 kHz.
All reactors listed are UL-recognized (UL-506 File #E53094) and CSA certified (CSA File #LR29753).

Table 3.10 – Recommended Motor Lead Lengths for Reliance Inverter Duty Motors

Maximum Lead Length in Feet with

460 VAC Motor

GV3000/SE

HP Rating

Filter Type

Carrier Frequency

2 kHz

4 kHz

8 kHz

1 to 2

None

500

500

500

3 to 5

500

500

500

7.5 to 10

750

500

500

15 to 20

800

500

500

25 to 60

800

500

500

75 to 100

800

500

500

125 to 150

800

500

500

200 to 400

1000

1000

1000

1 to 2

A 5% reactor/filter

at the drive.

1000

1000

1000

3 to 5

1000

1000

1000

7.5 to 10

1000

1000

1000

15 to 20

1000

1000

1000

25 to 60

1000

1000

1000

75 to 100

1000

1000

1000

125 to 150

1000

1000

1000

200 to 400

1000

1000

1000

Table 3.11 – Compatible Reactors

GV3000/SE

HP Rating

480 Volt

5% Reactor

GV3000/SE

HP Rating

480 Volt

5% Reactor

1

RL-00202

50

RL-08003

2

RL-00403

60

RL-08003

3

RL-00403

75

RL-10003

5

RL-00803

100

RL-13003

7.5

RL-01203

125

RL-16003

10

RL-01803

150

RL-20003

15

RL-02503

200

RL-25003

20

RL-03503

250

RL-32003

25

RL-03503

300

RL-40003

30

RL-04503

350

RL-50003

40

RL-05503

400

RL-50003

Advertising