However, if the Historian Server contains an interface-specific Trust entry that allows a
particular interface program to write data, you must have a Trust entry specific to buffering.
The following are the appropriate entries for the Application Name field of a Trust entry:
Buffering Application
Application Name field for Trust
Buffer Subsystem
PIBufss.exe
PI API Buffer Server
APIBE (if the PI API is using 4 character process
names)
APIBUF (if the PI API is using 8 character process
names)
To use a process name greater than 4 characters in length for a trust application name, use the
LONGAPPNAME=1 in the PIClient.ini file.
Enabling Buffering on an Interface Node with the ICU
The ICU allows you to select either PIBufss or Bufserv as the buffering application for your
interface node. Run the ICU and select Tools > Buffering.
Choose Buffer Type
To select PIBufss as the buffering application, choose Enable buffering with PI Buffer
Subsystem.
To select Bufserv as the buffering application, choose Enable buffering with API Buffer
Server.
If a warning message such as the following appears, click Yes.