modes. It is not possible for PI2 to have two values with the same timestamp.

InstrumentTag

Note: If the source tag name length exceeds 80 characters, users must use the
UserInt1 attribute for source point mapping. This is due to a limitation with the PI API
programming library which supports tag names of 80 characters or less for point ID
resolution.

Length

Depending on the version of the PI API and the Historian Server, this Interface supports an

InstrumentTag

attribute whose length is at most 32 or 1023 characters. The following table

indicates the maximum length of this attribute for all the different combinations of PI API
and Historian Server versions.

PI API

Historian Server

Maximum Length

1.6.0.2 or higher

2.x or higher

1023

1.6.0.2 or higher

Below 2.x

32

Below 1.6.0.2

2.x or higher

32

Below 1.6.0.2

Below 2.x

32

If the Historian Server version is earlier than 2.x or the PI API version is earlier than 1.6.0.2,
and you want to use a maximum

InstrumentTag

length of 1023, you need to enable the PI

SDK. See

Appendix B

for information.

Unless the

/tn

,

/tnex

, or

/ptid

interface parameter is used, the

InstrumentTag

can be

used to specify the source tag. The

ExDesc

and

Tag

attributes can also be used for source tag

name definition. The

UserInt1

attribute can be used to specify source tag by point ID

instead of tag name. The

How PItoPI Finds Source Points

section explains how the interface

parameters affect which receiving tag attributes are used for mapping to the source point and
the order that the attributes are searched for a mapping.

The interface checks the

InstrumentTag

attribute first. If the

InstrumentTag

is empty,

the extended descriptor is checked for

STAG=<tagname>

at the beginning of the

ExDesc

value. That is, the

ExDesc

attribute must begin with the „

STAG

‟ keyword. If neither

InstrumentTag

nor

ExDesc

has a tag name, the

UserInt1

attribute is checked for the

source tag point ID. Finally if none of these three attributes identify a source point, the
receiving tag name is used for the source tag name.

ExDesc

Note: If the source tag name length exceeds 80 characters, users must use the
UserInt1 attribute for source point mapping. This is due to a limitation with the PI API
programming library which supports tag names of 80 characters or less for point ID
resolution.

Length

Depending on the version of the PI API and the Historian Server, this Interface supports an

Extended

Descriptor

attribute whose length is at most 80 or 1023 characters. The