Historian Point Configuration

42

Location3
Value

Write
“I/O Timeout”

Write
“Access Denied”

Include
Snapshot

Point Level
Debugging

13

--

Yes

Yes

Yes

14

Yes

--

Yes

Yes

15

--

--

Yes

Yes

Location4

Scan-based Inputs

For interfaces that support scan-based collection of data,

Location4

defines the scan class

for the Historian point. The scan class determines the frequency at which input points are
scanned for new values. For more information, see the description of the

/f

parameter in the

Startup Command File

section.

Location5

Location5

attribute is used for setting the write mode for sending archive data to the

receiving Historian Server. The following table lists the supported modes for PI3 and PI2
receiving Historian Servers.

Location5

Write Mode

Description

Supported Historian
Server versions

0

ARCAPPEND

Archive and
Snapshot Data

Add archive event
regardless of existing
events.
Default snapshot
behavior is to append
data if event at
timestamp exists..

PI3 only*

1

ARCNOREPLACE

Archive Events
Only

Add archive event
unless event(s) exist at
same time.
Default snapshot
behavior is to append
data if event at
timestamp exists.

PI2 only

2

ARCREPLACE

Archive Events
Only

Add archive event,
replace if event at same
time.
Default snapshot
behavior is to append
data if event at
timestamp exists.

PI3 & PI2

3

ARCNOREPLACE

Archive and
Snapshot Events

Add archive or
snapshot event unless
event(s) exist at same
time

PI2 only

4

ARCREPLACE

Archive and
Snapshot Events

Add archive or
snapshot event, replace
if event at same time

PI3 & PI2

*Note: PI2 supports Insert (ARCNOREPLACE) or Replace (ARCREPLACE) data write