In this example, three-phase AC input power is supplied to two converter drives with the same power rating. This parallel
converter configuration increases the DC power supplied to the inverter drives.

Shared AC/DC Bus Hybrid Installation Example

IMPORTANT

In shared AC/DC hybrid configurations, the two converter drives must have the same power rating and must be greater than or
equal to the inverter drives. Refer to the Kinetix 5500 Servo Drives User Manual, publication

2198-UM001

, for system sizing

information, including restrictions on how many drives can be connected in the shared AC/DC, shared DC (common bus), and
hybrid configurations.

+

+

+

+

+

+

2198-H040-ERS

x

Common-bus (converter)

(frame 2) Leader Drives

2198-H008-ERS

x

Common-bus (inverter)

(frame 1) Follower Drives

2198-CAPMOD-1300 Capacitor Module
(optional component) Front View

2198-CAPMOD-1300 Capacitor Module
(optional component) Top View

2198-H

xxx-ERS

Kinetix 5500 Servo Drives are Shown

(top view)

Three-phase

Input Power

Shared AC (mains AC input)

Shared 24V (control power input)

Shared-bus Connection System
(front view)

AC Input

Connector

Control Power

Input Connector

Bus-bar Connectors and
AC Bus T-connectors

Bus-bar Connectors and
Control Power T-connectors

24V Control Input Power

Axis 1

Axis 2

Axis 3

Axis 4

Axis 5

2198-H040-ADP-IN

DC Bus

Shared DC Bus

DC Bus

Connector

Bus-bar Connectors and
DC Bus T-connectors

2198-H

xxx-ERS

Kinetix 5500 Servo Drives are Shown

(front view)

Axis 6

2198-H040-ADP-T

2198-H040-DP-T

2198-KITCON-CAP1300

(ships with capacitor module)