Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual

Page 9

Advertising
background image

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

9

Kinetix 5500 Drive Systems

In this example, three-phase AC power and 24V control power is shared in a shared-AC configuration. All drives must have
the same power rating (catalog number).

Shared AC Installation Example

IMPORTANT

In shared AC configurations, all drives must have the same power rating. Shared AC configurations do not support the
Bulletin 2198 capacitor module. Refer to the Kinetix 5500 Servo Drives User Manual, publication

2198-UM001

, for system sizing

information, including restrictions on how many drives can be connected in the shared AC configuration.

+

+

+

+

Kinetix 5500 Servo Drives (top view)

2198-H008-ERS (frame 1) Drives are Shown

Three-phase

Input Power

Kinetix 5500 Servo Drives (front view)

2198-H008-ERS (frame 1) Drives are Shown

Shared AC (mains AC input)

Shared 24V (control power input)

Shared-bus Connection System
(front view)

AC Input

Connector

Control Power

Input Connector

Bus-bar Connectors and
AC Bus T-connectors

Bus-bar Connectors and
Control Power T-connectors

24V Control
Input Power

Axis 1

Axis 2

Axis 3

Axis 4

Axis 5

2198-H040-ADP-IN

2198-H040-AP-T

The 2198-H040-ADP-IN

connector kit also includes a

DC-bus T-connector, but is not

used in this configuration.

Advertising