Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual
Page 9

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014
9
Kinetix 5500 Drive Systems
In this example, three-phase AC power and 24V control power is shared in a shared-AC configuration. All drives must have
the same power rating (catalog number).
Shared AC Installation Example
IMPORTANT
In shared AC configurations, all drives must have the same power rating. Shared AC configurations do not support the
Bulletin 2198 capacitor module. Refer to the Kinetix 5500 Servo Drives User Manual, publicatio
, for system sizing
information, including restrictions on how many drives can be connected in the shared AC configuration.
+
+
+
+
Kinetix 5500 Servo Drives (top view)
2198-H008-ERS (frame 1) Drives are Shown
Three-phase
Input Power
Kinetix 5500 Servo Drives (front view)
2198-H008-ERS (frame 1) Drives are Shown
Shared AC (mains AC input)
Shared 24V (control power input)
Shared-bus Connection System
(front view)
AC Input
Connector
Control Power
Input Connector
Bus-bar Connectors and
AC Bus T-connectors
Bus-bar Connectors and
Control Power T-connectors
24V Control
Input Power
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
2198-H040-ADP-IN
2198-H040-AP-T
The 2198-H040-ADP-IN
connector kit also includes a
DC-bus T-connector, but is not
used in this configuration.