Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual

Page 80

Advertising
background image

80

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

Kinetix 5500 Drive Systems

Performance Specifications with Frame 70 Linear Thrusters

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Linear Thruster
Cat. No.

Velocity, max
460V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
460V AC
kW

Kinetix 5500 Drives
(480V AC input)

LDAT-S072010-DD

x

3.9

6.0

364 (82)

22.0

1055 (237)

1.37

2198-H025-ERS

x

LDAT-S072020-DD

x

5.0

1.64

LDAT-S072030-DD

x

LDAT-S072070-DD

x

LDAT-S072010-ED

x

3.5

3.0

11.0

1.03

2198-H015-ERS

x

LDAT-S072020-ED

x

LDAT-S072070-ED

x

LDAT-S073010-DD

x

4.4

9.0

554 (125)

32.8

1576 (354)

2.27

2198-H040-ERS

x

LDAT-S073020-DD

x

LDAT-S073070-DD

x

5.0

2.50

LDAT-S073010-ED

x

LDAT-S073070-ED

x

2.4

3.0

10.9

1.01

2198-H015-ERS

x

LDAT-S074010-DD

x

4.7

11.9

730 (164)

43.5

2088 (469)

3.15

2198-H040-ERS

x

LDAT-S074020-DD

x

LDAT-S074070-DD

x

5.0

3.30

LDAT-S074010-ED

x

LDAT-S074070-ED

x

3.5

6.0

21.7

2.08

2198-H025-ERS

x

LDAT-S076010-DD

x

5.0

18.2

1122 (252)

66.4

3189 (717)

5.02

2198-H070-ERS

x

LDAT-S076020-DD

x

LDAT-S076070-DD

x

LDAT-S076010-ED

x

LDAT-S076070-ED

x

3.5

9.1

33.2

3.18

2198-H040-ERS

x