Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

5

Kinetix 5500 Drive Systems

In this example, a non-safety controller makes the Motion-only connection and a separate GuardLogix safety controller
makes the Safety-only connection with the 2198-H

xxx-ERS2 drives.

Motion and Safety Configuration (multi-controller)

IMPORTANT

If two controllers are used in an application with Motion-only and Safety-only connections, the Safety-only connection must
be a 1756-L7

xS GuardLogix safety controller and the Motion-only connection must be a ControlLogix 1756-L7x or

CompactLogix 5370 controller.

1606-XL

Po we r S u p p l y

Input

Allen-Bradley

LNK1LNK2 NET OK

EtherNet/IP

1

2

LNK1LNK2 NET OK

EtherNet/IP

1

2

1585J-M8CBJM-

x

Ethernet (shielded) Cable

GuardLogix 1756-L7

xS Controller

Logix Designer

Application

(version 24.0 or later)

AC Input Power

2198-H

xxx-ERS2 Servo Drives

(top view)

2198-H

xxx-ERS2 Servo Drives

(front view)

Digital Inputs to Sensors and Control String

1606-XL

xxx

24V DC Control, Digital Inputs,

and Motor Brake Power

(customer-supplied)

Kinetix VP

Servo Motors

2198-CAPMOD-1300 Capacitor Module

(optional component)

1734-AENTR
POINT Guard I/O
EtherNet/IP Adapter

1783-BMS

Stratix 5700

Switch

CompactLogix 5370 Controller or
ControlLogix 1756-L7

x Controller

(ControlLogix controller is shown)

Motion Program

Module Definition

Configured with

Motion only

Connection

Safety Program

Module Definition

Configured with Safety

only Connection

Safety
Device