Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

19

Kinetix 5500 Drive Systems

Kinetix 5500 (200V-class operation) Drives/Kinetix VP Low Inertia Motor Curves (continued)

Torque

(N•m)

Torque
(lb•in)

0

0

6.0

12.0

18.0

30.0

24.0

53.1

106

159

212

265

2198-H040-ERS

x and VPL-A1304A

Speed (rpm)

0

1000

2000

1500

500

Torque

(N•m)

Torque
(lb•in)

2198-H070-ERS

x and VPL-A1303F

24.0

20.0

16.0

12.0

8.0

4.0

0

Speed (rpm)

212

177

142

106

70.8

35.4

0

0

2000

4000

3000

1000

Torque

(N•m)

Torque
(lb•in)

0

0

6.0

12.0

18.0

30.0

24.0

53.1

106

159

212

265

2198-H070-ERS

x and VPL-A1304D

Speed (rpm)

0

2000

3000

1000

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

500

1000

1500

2000

0

2198-H070-ERS

x and VPL-A1306C

40.0

35.0

30.0

25.0

20.0

15.0

10.0

5.0

0

354

310

265

221

177

133

88.5

44.2

0

= Intermittent operating region
= Continuous operating region
= Drive operation with 200V AC rms input voltage

Advertising