Performance Specifications with Frame 50 Linear Thrusters

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Linear Thruster
Cat. No.

Velocity, max
460V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
460V AC
kW

Kinetix 5500 Drives
(480V AC input)

LDAT-S051010-DD

x

2.8

3.1

119 (27)

11.4

363 (82)

0.34

2198-H015-ERS

x

LDAT-S051020-DD

x

3.7

0.43

LDAT-S051030-DD

x

4.1

0.49

LDAT-S051040-DD

x

4.4

0.53

LDAT-S051050-DD

x

4.7

0.55

LDAT-S052010-DD

x

3.7

6.2

251 (56)

22.7

727 (163)

0.92

2198-H025-ERS

x

LDAT-S052020-DD

x

4.8

1.20

LDAT-S052030-DD

x

5.0

1.24

LDAT-S052040-DD

x

LDAT-S052050-DD

x

LDAT-S052010-ED

x

3.7

3.1

11.4

0.80

2198-H015-ERS

x

LDAT-S052020-ED

x

4.6

0.98

LDAT-S052030-ED

x

4.6

1.02

LDAT-S052040-ED

x

LDAT-S052050-ED

x

LDAT-S053010-DD

x

4.1

9.4

378 (85)

34.2

1093 (246)

1.56

2198-H040-ERS

x

LDAT-S053020-DD

x

5.0

1.87

LDAT-S053030-DD

x

LDAT-S053050-DD

x

LDAT-S053010-ED

x

LDAT-S053050-ED

x

3.5

3.1

11.4

1.04

2198-H015-ERS

x

LDAT-S054010-DD

x

4.4

12.4

509 (114)

45.5

1453 (327)

2.26

2198-H040-ERS

x

LDAT-S054020-DD

x

LDAT-S054050-DD

x

5.00

2.53

LDAT-S054010-ED

x

4.4

6.2

22.7

1.87

2198-H025-ERS

x

LDAT-S054020-ED

x

LDAT-S054050-ED

x

5.0

2.05