Kinetix 5500 (400v) with vpf, Bulletin vpf motor cable combinations – Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual

Page 34

Advertising
background image

34

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

Kinetix 5500 Drive Systems

Kinetix 5500 (200V-class operation) Drives/Kinetix VP Food Grade Motor Curves (continued)

Kinetix 5500 (400V-class operation) Drives with Kinetix VP Food Grade Motors

This section provides system combination information for the Kinetix 5500 drives (with 480V, nominal input) when
matched with Kinetix VP (400V-class) food-grade motors. Single cable catalog numbers, system performance
specifications, and the optimum torque/speed curves are included.

Bulletin VPF Motor Cable Combinations

Motor Cat. No. (400V-class)

Feedback Type

Single Cable Cat. No.

(1)

(1) Cable length

xx is in meters, 01 (3.3)…50 (164) in 1.0 m (3.3 ft) increments. Refer to the Kinetix Motion Accessories Technical Data, publication

GMC-TD004

, for cable specifications.

For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Single Motor Cable Overview beginning on

page 11

.

VPF-B0632F, VPF-B0632T, VPF-B0633M, VPF-B0633T

Multi-turn or Single-turn
Digital Encoder Feedback

2090-CSBM1DF-18AA

xx or

2090-CSWM1DF-18AA

xx (standard, non-flex)

2090-CSBM1DF-18AF

xx (continuous-flex)

VPF-B0752E, VPF-B0752F, VPF-B0753E, VPF-B0753F

VPF-B1001M

, VPF-B1002E, VPF-B1003C

VPF-B0752M, VPF-B0753M

2090-CSBM1DF-14AA

xx or

2090-CSWM1DF-14AA

xx (standard, non-flex)

2090-CSBM1DF-14AF

xx (continuous-flex)

VPF-B1002M, VPF-B1003F, VPF-B1003T

VPF-B1153E, VPF-B1153F

VPF-B1303C

, VPF-B1303F, VPF-B1304C, VPF-B1304E

VPF-B1652C

Bulletin VPF Motor Performance Specifications with Kinetix 5500 (400V-class operation) Drives

Motor Cat. No.

Rated Speed,
max
rpm

System Continuous
Stall Current
A (0-pk)

System Continuous
Stall Torque
N•m (lb•in)

System Peak
Stall Current
A 0-pk

System Peak
Stall Torque
N•m (lb•in)

Motor Rated
Output
kW (Hp)

Speed at Motor
Rated Output
rpm

Kinetix 5500 Drives
(480V AC input)

VPF-B0632F

4600

1.20

0.93 (8.0)

3.50

2.26 (20.0)

0.34 (0.46)

4600

2198-H003-ERS

x

4.20

2.69 (24.0)

2198-H008-ERS

x

VPF-B0632T

8000

2.55

0.93 (8.0)

8.75

2.69 (24.0)

0.41 (0.55)

8000

2198-H008-ERS

x

VPF-B0633M

6700

2.50

1.27 (11.0)

8.75

4.09 (36.0)

0.49 (0.66)

6700

2198-H008-ERS

x

Torque

(N•m)

Torque
(lb•in)

0

0

6.0

12.0

18.0

30.0

24.0

53.1

106

159

212

265

2198-H070-ERS

x and VPF-A1304D

Speed (rpm)

0

2000

3000

1000

= Intermittent operating region
= Continuous operating region
= Drive operation with 200V AC rms input voltage

Advertising