Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual

Page 98

Advertising
background image

98

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

Kinetix 5500 Drive Systems

Kinetix 5500 Drives/MP-Series (ball screw) Electric Cylinder Curves

2000

1600

1200

800

400

0

45.0

36.0

27.0

18.0

9.0

0

Force

(N)

Force
(lb)

Velocity (mm/s)

50

200

150

0

305

250

100

2198-H008-ERSx and MPAI-A2076CV1
2198-H003-ERSx and MPAI-B2076CV1

2000

1600

1200

800

400

0

45.0

36.0

27.0

18.0

9.0

0

Force

(N)

Force
(lb)

Velocity (mm/s)

50

200

150

0

305

250

100

2198-H008-ERSx and MPAI-A2xxxCV3
2198-H003-ERSx and MPAI-B2xxxCV3

5000

4000

3000

2000

1000

0

1124

899

674

450

225

0

Force

(N)

Force
(lb)

Velocity (mm/s)

50

200

150

0

305

250

100

2198-H008-ERSx and MPAI-A3076CM1

2198-H008-ERSx and MPAI-B3076CM1

2198-H008-ERSx and MPAI-A3076EM1
2198-H008-ERSx and MPAI-B3076EM1

Force

(N)

Force
(lb)

3000

2500

2000

1500

1000

500

0

674

562

450

337

225

112

0

Velocity (mm/s)

100

400

300

0

610

500

200

5000

4000

3000

2000

1000

0

1124

899

674

450

225

0

Force

(N)

Force
(lb)

Velocity (mm/s)

50

200

150

0

300

250

100

2198-H015-ERSx and MPAI-A3xxxCM3

2198-H008-ERSx and MPAI-B3xxxCM3

5000

4000

3000

2000

1000

0

1124

899

674

450

225

0

Force

(N)

Force
(lb)

Velocity (mm/s)

100

400

300

0

600

500

200

2198-H015-ERSx and MPAI-A3xxxEM3
2198-H008-ERSx and MPAI-B3xxxEM3

= Continuous operating region @ 25 °C (77 °F)
= Continuous operating region @ 40 °C (104 °F)
= Intermittent operating region, 450 mm (18 in.) stroke length only
= Intermittent operating region, 076…300 mm (3…12 in.) stroke lengths

Advertising