Rockwell Automation 2198-Hxxx Kinetix 5500 Drive Systems Design Guide User Manual

Page 70

Advertising
background image

70

Rockwell Automation Publication GMC-RM009D-EN-P - June 2014

Kinetix 5500 Drive Systems

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Performance Specifications with Frame 70 Linear Thrusters

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

LDAT-S053010-DD

x

4.1

9.4

378 (85)

34.2

1093 (246)

1.31

2198-H040-ERS

x

LDAT-S053020-DD

x

5.0

1.53

LDAT-S053030-DD

x

LDAT-S053050-DD

x

5.0

1.53

LDAT-S053010-ED

x

LDAT-S053050-ED

x

1.7

3.1

11.4

0.47

2198-H015-ERS

x

LDAT-S054010-DD

x

4.4

12.4

509 (114)

45.5

1453 (327)

1.87

2198-H040-ERS

x

LDAT-S054020-DD

x

LDAT-S054050-DD

x

5.0

2.05

LDAT-S054010-ED

x

LDAT-S054050-ED

x

2.6

6.2

22.7

1.02

2198-H025-ERS

x

Linear Thruster
Cat. No.

Velocity, max
230V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
230V AC
kW

Kinetix 5500 Drives
(240V AC input)

LDAT-S072010-DD

x

LDAT-S072070-DD

x

3.5

6.0

364 (82)

22.0

1055 (237)

1.03

2198-H025-ERS

x

LDAT-S072010-ED

x

LDAT-S072070-ED

x

1.7

3.0

11.0

0.47

2198-H015-ERS

x

LDAT-S073010-DD

x

LDAT-S073070-DD

x

3.5

9.0

554 (125)

32.8

1576 (354)

1.57

2198-H040-ERS

x

LDAT-S073010-ED

x

LDAT-S073070-ED

x

1.2

3.0

10.9

0.41

2198-H015-ERS

x

LDAT-S074010-DD

x

LDAT-S074070-DD

x

3.5

11.9

730 (164)

43.5

2088 (469)

2.08

2198-H040-ERS

x

LDAT-S074010-ED

x

LDAT-S074070-ED

x

1.8

6.0

21.7

0.95

2198-H025-ERS

x

LDAT-S076010-DD

x

LDAT-S076070-DD

x

3.5

18.2

1122 (252)

66.4

3189 (717)

3.17

2198-H070-ERS

x

LDAT-S076010-ED

x

LDAT-S076070-ED

x

1.8

9.1

33.2

1.45

2198-H040-ERS

x

Performance Specifications with Frame 50 Linear Thruster (cont.)

Linear Thruster
Cat. No.

Velocity, max
230V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
230V AC
kW

Kinetix 5500 Drives
(240V AC input)

Advertising