Kinetix 5500 (200V-class operation) Drives/Kinetix VP Low Inertia Motor Curves (continued)
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H025-ERS
x and VPL-A1001M
35.4
26.5
17.7
8.85
0
4.0
3.0
2.0
1.0
0
0
4000
8000
6000
2000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H015-ERS
x and VPL-A1001C
35.4
26.5
17.7
8.85
0
0
2000
4.0
3.0
2.0
1.0
0
3000
1000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H040-ERS
x and VPL-A1002F
70.8
53.1
35.4
17.7
0
8.0
6.0
4.0
2.0
0
0
3000
5000
4000
1000
2000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H025-ERS
x and VPL-A1002C
70.8
53.1
35.4
1.77
0
0
2000
8.0
6.0
4.0
2.0
0
3000
1000
Torque
(N•m)
Torque
(lb•in)
2198-H040-ERS
x and VPL-A1003E
12.0
10.0
8.0
6.0
4.0
2.0
0
Speed (rpm)
106
88.5
70.8
53.1
35.4
17.7
0
0
2000
4000
3000
1000
Torque
(N•m)
Torque
(lb•in)
2198-H025-ERS
x and VPL-A1003C
12.0
10.0
8.0
6.0
4.0
2.0
0
Speed (rpm)
0
1500
2500
2000
500
1000
106
88.5
70.8
53.1
35.4
17.7
0
= Intermittent operating region
= Continuous operating region
= Drive operation with 200V AC rms input voltage