Install row harnesses, Install row harnesses on towers, Install center section row harness – Great Plains NTA2007HD Predelivery Manual User Manual

Page 82

Advertising
background image

78

Great Plains Manufacturing, Inc.

Contents

Index

NTA607HD

166-283Q

Contents

Index

02/09/2011

Install Row Harnesses

Refer to Figure 141

Row harnesses

collect blockage sensor

data

and present it to the WSMB

. Normally, the sensors

connected are located on the same tower as the row har-
ness - where they are not, an extension (

,

or

)

is provided.

Connection of sensor leads

is completed at Connect

Sensor Leads” on page 85.

Install Row Harnesses on Towers

312. Select one of:

467751320S1 DJ 12 ROW HARNESS

or

467751330S1 16 ROW HARNESS

Note: Row harnesses vary with row spacing, hopper

count and single- vs. double-shoot. However, all
row harnesses on a single implement must be the
same part number.

313. Using two large cable ties provided in the

DICKEY-john

®

kit, secure the potted harness

module

to the tower tube. Orient the module:

• behind the plate bearing the WSMB,
• cables exiting downward, and
• top of the module about 13cm (5in) below turret.
Apply ties below the center of the module.

Repeat step 312 and step 313 for each tower.

Install Center Section Row Harness

Refer to Figure 142 (which depicts this area at a later stage
of assembly)

314. Select one of:

467751320S1 DJ 12 ROW HARNESS

or

467751330S1 16 ROW HARNESS

315. Using two large cable tie provided in the

DICKEY-john

®

kit, secure the potted harness

module

to the WSMB mount

. Orient the

module:
• rear face of mount

,

• right end slots of mount

, and

• cables exiting downward.
Apply ties below the center of the module.

Null4:

Null4:

Figure 141

Row Harness Elements

Q0081

167

159

152

160

154

155

2

160

159

167

152 154

155

2

160

Null4:

Figure 142

Center (5th) Row Monitor Harness

Q0082

130

167

160

160

160

160

130

130

130

Advertising