Sensors, Power – ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 11

Advertising
background image

1-4 ADS TRITON+ Manual

Sensors

The TRITON+ monitor supports several approved IS sensors that
vary in measurement methodology, redundancy, and other features.
The monitor is approved for accommodating up to two of the same
or different types of IS sensors. Following are the approved IS
sensors:

Peak Combo Sensor Performs upward ultrasonic depth,
pressure depth, and peak velocity measurement and mounts at
or near the bottom of the pipe under the flow surface (ADS p/n
8K-CS4-05-35, 8K-CS4-15-35, or 8K-CS4-30-1H).

Surface Combo Sensor Performs downward ultrasonic
depth, surcharge pressure depth, surcharge peak velocity, and
surface velocity measurement and mounts at the top (or crown)
of the pipe above the flow (ADS p/n 8K-CS5-V2-05-30, 8K-
CS5-V2-15-30, or 8K-CS5-V2-30-1H).

Ultrasonic Depth Sensor Performs downward ultrasonic
depth measurement alone and mounts at the top (or crown) of
the pipe above the flow (ADS p/n 8K-CS5-D1-00-30).

Extension cables are available for these sensors in lengths up to a
maximum of 300 feet (91 m). .

Note: Detailed descriptions and specifications for the
sensors are available in Chapter 2, System Overview, and
Appendix A, Specifications

Power

The TRITON+ flow monitor is powered by an internal 12-volt IS
battery pack (ADS p/n 8000-0043) or an external DC power source
through an external power and communications unit (ExPAC, ADS
p/n 8000-0377), external Modbus interface unit (XBUS

, ADS p/n

9000-0427), or an external input/output device (XIO

, ADS p/n

8000-0400).

Note: Using a battery pack that is not supplied by ADS
will void the warranty and IS certification of the monitor.