Analog and Digital I/O 8-19

4. Test the digital outputs in one of the following ways, and then

verify that the customer’s device received the change in relay
status:

 Adjust your event triggers in Qstart to force an event and

subsequent return-to-normal to occur over a limited period
of time. If you choose this testing option, remember to
reset your event triggers and reactivate the monitor
following the test.

 Modify the environmental conditions at the monitoring

location to trigger an event and return-to-normal over a
limited period of time.